15. Puller (commercially available)
SL-710A
98
15. Puller (commercially available)
DANGER
Wait at least 10 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the face plate of the control box. Touching areas where high voltages are present can result in
severe injury.
15-1. Timing
Obtain the puller output from the CN15 connector on the
control circuit board.
• The puller is lowered after the 40th stitch from the
sewing start.
• After the sewing machine stops, it is raised together
with the automatic presser lifter, and then after 10
seconds it is lowered.
Note:
The 40th stitch and 10 seconds settings given above can
be changed by changing the parameter settings.
15-2. Connector
The following puller connector is provided.
Part name Part code
Puller connector assembly J03126-001
<Note>
If purchasing the connector as a single part from the
manufacturer, specify the following number.
Manufacturer MOLEX
Connector No. 5557-10R
Connector terminal 5556PBTL
Terminal puller 57031-6000
15-3. Binding the cord
Secure the puller cord (1) using a cable tie (2).
1869M
<CN15>
(1) Puller output
(6) Puller power supply
1870M
1871M
(1)
(2)