V - 27
WSW14 (AUTO ANS facility setting)
Selector
No.
Function Setting and Specifications
1
2
Frequency band selection
(Lower limit)
No. 1 2
0 0 : 13 Hz
0 1 : 15 Hz
1 0 : 23 Hz
1 1 : 20 Hz
3
4
Frequency band selection
(Upper limit)
No. 3 4
0 0 : 30 Hz
0 1 : 55 Hz
1 X : 70 Hz
5
|
8
No. of rings in AUTO ANS mode
No. 5 6 7 8
0 0 0 0 : Fixed to once
0 0 0 1 : Fixed to 2 times
0 0 1 0 : Fixed to 3 times
0 0 1 1 : Fixed to 4 times
0 1 0 0 : 1 to 2 times
0 1 0 1 : 1 to 3 times
0 1 1 0 : 1 to 4 times
0 1 1 1 : 1 to 5 times
1 0 0 0 : 2 to 3 times
1 0 0 1 : 2 to 4 times
1 0 1 0 : 2 to 5 times
1 0 1 1 : 2 to 6 times
1 1 0 0 : 1 to 10 times
1 1 0 1 : 2 to 10 times
1 1 1 0 : 3 to 5 times
1 1 1 1 : 4 to 10 times
l Selectors 1 through 4: Frequency band selection
These selectors are used to select the frequency band of calling signals for activating the AUTO
ANS facility.
In the French versions, if the user sets the PBX to OFF from the control panel, the setting made by
selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even if
the setting made by these selectors does not apply, it will be printed on the configuration list.)
l Selectors 5 through 8: No. of rings in AUTO ANS mode
These selectors set the number of rings to initiate the AUTO ANS facility.