V - 42
WSW29 (Function setting 7)
Selector
No.
Function Setting and Specifications
1
|
3
Compression threshold level for
voice signals inputted via the
network in the built-in TAD
operation
No. 1 2 3
0 0 0 : -47.0 dBm (A)
0 0 1 : -48.5 dBm (B)
0 1 0 : -50.0 dBm (C)
0 1 1 : -51.5 dBm (D)
1 0 0 : -53.0 dBm (E)
1 0 1 : -54.5 dBm (F)
1 1 0 : -56.0 dBm (G)
1 1 1 : OFF (H)
4
|
6
Compression threshold level for
voice signals inputted via the
handset in the built-in TAD
operation
No. 4 5 6
0 0 0 : -44.0 dBm (A)
0 0 1 : -45.5 dBm (B)
0 1 0 : -47.0 dBm (C)
0 1 1 : -48.5 dBm (D)
1 0 0 : -50.0 dBm (E)
1 0 1 : -51.5 dBm (F)
1 1 0 : -53.0 dBm (G)
1 1 1 : OFF (H)
7
Automatic dialing by caller IDs
stored in the memory
0: Yes 1: No
8
Beep when the memory area for
the activity report becomes full
0: No 1: Yes
NOTE: WSW29 is applicable to those models equipped with a built-in TAD.
NOTE: Selector 7 is applicable to those versions supporting the caller ID service. Note that it is not
applicable to the U.S.A. versions.
NOTE: Selector 8 is applicable to the European versions only.
l Selectors 1 through 6: Compression threshold level for voice signals inputted via the network/
handset in the built-in TAD operation
If voice signals inputted via the network or handset are below the level specified by these
selectors, the TAD interprets those received voice signals as no signal, compressing the recording
time.
l Selector 7: Automatic dialing by caller IDs stored in the memory
This selector determines whether or not the automatic dialing function by caller IDs stored in the
memory (see the Note below) can be accessed.
If it is set to "0," caller IDs stored in the memory can be called up on the LCD by the user function
6-7 and then pressing the Start key when the desired caller ID is displayed dials the caller
automatically.
(Note: The equipment can store a maximum of the latest 30 incoming caller IDs together with the
reception date and time in the memory.)
l Selector 8: Beep when the memory area for the activity report becomes full
If this selector is set to "1," the equipment will beep when the memory area for the activity report
becomes full (as well as displaying a message on the LCD, prompting the output of the activity
report).