S-7200A
4. FUNCTION SETTINGS
10
Function No. 47−60
No. Initial value Setting range Setting details
47 0
0–1
Operation during standing operation when AUTO function is on
0: Operation stops when high speed pedal turns back on, and restarts when
off
1: Above function is not used
48 0
0–1
Thread trimming pedal function after thread trimming during standing
operation
0: Presser foot can be raised and lowered
1: Above operation not used (only possible using presser foot lifter pedal)
49 0
0–1
Alternate standing operation pedal and treadle operation (See NOTE 15)
0: Treadle operation is disabled after standing operation pedal is used
1: Treadle operation can also be used after standing operation pedal is used
(alternate operation is possible)
51* 0
0–1
Correction stitch sewing using actuator switch after thread trimming
0: Not possible (switch operation disabled)
1: Possible
52 2 (needles)
1–99 (needles)
Number of slow start stitches
53*
10
(needles)
0–100
(needles)
Count units for stitch counter display
0: No counting operation
1–100: Display counts down by number of stitches set
54* 1
0–2
Operation when stitch counter warning occurs ("!" icon is illuminated)
0: Starting using treadle is enabled as normal
1: Starting using treadle is disabled (thread trimming by depressing treadle
backward is possible)
2: Starting using treadle is completely disabled once treadle is returned to
neutral and operation stops
55
(NOTE 16)
0
0–1
Operation after treadle is depressed backward or knee switch is operated
when presser foot is raised
0: When treadle is returned to neutral, presser foot is raised
1: When treadle is returned to neutral, presser foot is lowered
56 0
0–1
Function for preventing needle bar operation when treadle is accidentally
depressed forward when it is returned to neutral after being depressed
backward
0: Used
1: Not used
57
(NOTE 17)
0
0–1
Operation when treadle is depressed forward to 1st step when presser foot is
raised
0: Presser foot is lowered
1: Presser foot is not lowered
58 0
0–1
Presser foot soft up function
0: Not used
1: Used (Function No. 59 and No. 60 must be set.)
59 0 (ms)
0–150 (ms)
60 0 (ms)
0–99 (ms)
Presser foot soft up timer setting
(When Function No. 58 is set to "1")
(NOTE 15) Presser foot lifter pedal operation is not included. In the case of simultaneous operation, the standing operation
pedal takes priority.
(NOTE 16) Setting is only enabled when DIP switch 1 is set to ON.
(NOTE 17) Setting is only enabled when DIP switch 2 is set to ON.
*… Settings indicated with " * " are enabled when the power is turned off and then back on.
(fully ON)
Presser foot lifting
2247M