5. ADJUSTMENT
BAS-7610
5-05
5-2.
Adjusting the needle bar height and, the needle and the rotary hook timing
Remove the slide plate (the needle plate), the bottom plunger and the work clamp while making this adjustment.
<Adjusting the needle bar height>
Turn the pulley to set the needle bar (1) to its lowest position. Put the side “1” of the gauge (2) at the end edge of the
needle bar (1). Adjust Remove the rubber cap (3), Loose the screw (4)
<Adjusting the rotary hook>
This adjustment is performed in order to prevent the damage to inner rotary hook with a needle. (The rotary hook life is
influenced.)
Perform this adjustment, when needle is exchanged. (Since special rotary hook is used, be sure to use the exclusive
needle.)
Remove the bobbin case holder position bracket while making this adjustment.
Inner rotary hook is rotated so that the needle receptacle part may turn down.
<Timing of the needle and the rotary hook> of the following clause is performed.
The needle receptacle part is returned upwards.
Turn the machine pulley to move the needle bar its lowest position.
It checks that the needle has not hit the needle receptacle part.
When hitting, it reattaches so that the needle may meet the needle receptacle.
1316S
(1)
(2)
(1)
(3)
(4)
1317S
1676S
1677S
1678S
Needle receptacle part
Needle
Needle receptacle part