1.4.19 Print Network Configuration
This function is to print the wired or wireless network setting information. (Network items of
Printer Settings are printed.)
When this function is used for a model without LAN or when the LAN function is disabled
through the PJL setting, a test pattern is printed.
1.4.20 Change ON/OFF setting for sleep function
This function allows you to change the sleep function setting to ON or OFF.
Each time this mode is entered, all LEDs light for one second and the setting applied is
reversed. When the setting is completed, the machine returns to the ready state.
1.4.21 Reset developer roller counter 1, 2, 3 or 4 (Common to all models)
This function allows you to manually perform the same operation as when the toner cartridge
is replaced with a new one. The purpose of this function is to provide an error resetting
method in the event that the toner life was not cleared because the new toner cartridge was
not detected by the machine for any reason.
Reset developer roller counter 1: Execute when replacing with Starter Toner.
Reset developer roller counter 2: Execute when replacing with Standard Toner.
Reset developer roller counter 3: Execute when replacing with High Yield Toner.
Reset developer roller counter 4: Execute when replacing with Super High Yield Toner.
1.4.22 USB speed lock mode
This function allows you to change the USB speed setting to Lock to FULL or Automatic
change (HIGH/FULL). The setting applied is reversed each time this mode is entered.
(The same function as WSW48 described in "1.3.3 Set worker switches (WSW) (function
code: 10)" in this chapter)
The setting currently applied can be determined by pressing the [Go] button nine times and
checking the LED status after several seconds. When the setting is completed, the machine
returns to the ready state.
LED display USB speed setting
Toner LED lights for one second. Automatic change (default) Lock to FULL
Drum LED lights for one second. Lock to FULL Automatic change