Brother HL-5450DNT Service Manual Page 76

  • Download
  • Add to my manuals
  • Print
  • Page
    / 313
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 75
2-40
Confidential
Error codes 7B00 and 7C00
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
An unidentified error occurred.
Error code 7D00
Detected discharge that may be attributable to dirty corona wire on the drum unit.
Error codes 7E00 to 8200
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
An unidentified error occurred.
Error code 8300
Detected discharge when the number of rotations of the drum has exceeded twice the life
limit.
---
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Drum Error
<User Check>
Slide the green tag of the drum unit left and right two to three times to clean the corona
wire.
Replace the drum unit with a new one.
Step Cause Remedy
1
High-voltage power supply PCB
failure
Replace the high-voltage power supply PCB
ASSY.
2 Main PCB failure Replace the main PCB ASSY.
---
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Drum Stop
<User Check>
Replace the drum unit with a new one, and reset the drum counter.
Step Cause Remedy
1
High-voltage power supply PCB
failure
Replace the high-voltage power supply PCB
ASSY.
2 Main PCB failure Replace the main PCB ASSY.