Brother HL-5450DNT Service Manual Page 91

  • Download
  • Add to my manuals
  • Print
  • Page
    / 313
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 90
2-55
Confidential
Error code EF00
The supplied power is unstable.
Error code F000
Malfunction of the flash memory on the main PCB
Error codes F100 to F800
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
An unidentified error occurred.
Print Unable EF
<User Check>
Turn OFF the power switch. After several seconds, turn ON the power again and check
that this error is reset.
Step Cause Remedy
1
Low-voltage power supply PCB
failure
Replace the low-voltage power supply PCB
ASSY, and then reset the irregular power
supply detection counter.
2 Main PCB failure Replace the main PCB ASSY.
CAUTION:
The irregular power supply detection error (error code EF00) occurs when there is a
large distortion in the power supply voltage supplied to the machine. In this case, if the
same power supply is used, the same error may occur even when the low-voltage
power supply PCB ASSY is replaced. Ask the user to review the installation
environment.
Print Unable F0
<User Check>
Turn OFF the power switch. After several seconds, turn ON the power again and check
that this error is reset.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
---
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Page view 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 312 313

Comments to this Manuals

No comments