Troubleshooting and routine maintenance
141
C
Error and maintenance messages C
As with any sophisticated office product, errors may occur and consumable items may need to be
replaced. If this happens, your machine identifies the error or required routine maintenance and
shows the appropriate message. The most common error and maintenance messages are shown
below.
You can correct most errors and perform routine maintenance by yourself. If you need more help,
the Brother Solutions Center offers the latest FAQs and troubleshooting tips:
Visit us at http://solutions.brother.com/
Error Message Cause Action
Access Error
(MFC-9320CW only)
The device is removed from the
USB direct interface while the
data is processing.
Press Stop/Exit. Reinsert the device and try
to print with Direct Print.
Belt End Soon The belt unit is near the end of its
life.
Buy a new belt unit before you get a
Replace Belt message.
Calibrate Calibration failed. Press Black Start or Color Start and try it
again.
Turn off the machine. Wait a few
seconds, then turn it on again.
Identify the color causing the problem
and put in a new drum unit. (See
Replacing the drum units on page 174.)
To identify the color of the drum unit, visit
us at http://solutions.brother.com/
to view
our FAQs and troubleshooting tips.
Put in a new belt unit. (See Replacing the
belt unit on page 178.)
Put in a waste toner box. (See Replacing
the waste toner box on page 182.)
If the problem continues, call your dealer
or Brother Customer Service.
Cartridge Error
Put the Black (K)
Toner Cartridge
back in.
1
1
The toner cartridge
color with the problem
is shown in the
message.
The toner cartridge is not installed
properly.
Take out the drum unit and toner cartridge
assembly for the toner color that is indicated
on the LCD. Remove the toner cartridge and
then re-install it in the drum. Put the drum
unit and toner cartridge assembly back into
the machine again.