DB2-DD7100A 146
Problem
Possible cause Page
15. TROUBLESHOOTING
14. Oil gauge is not visible in oil
sight glass.
Is the oil tank empty?
Fill the oil tank with oil.
Is the oil gauge damaged?
Replace the oil gauge.
Oil gauge
15
15. "ou" flashes in LED display
when power is turned on.
Is the power supply voltage
abnormally high?
Check that the power supply
voltage matches the control
box voltage specifications.
Voltage rating label
Is the synchronizer connector inside
the control box disconnected?
Insert the connector securely.
16. "U" flashes in LED display
when power is turned on.
19
17. "UE" flashes in LED display
when power is turned on and
treadle is pressed.
Is detector pin q of the bobbin thread
detector not retracted correctly?
Retract the detector pin q.
Use an Allen key to move the slider w,
and check that the detector pin
q moves
correctly.
q
w
119
18. "oF" flashes in LED display
when power is turned on and
treadle is pressed.
Is the machine connector inside
the control box disconnected?
Insert the connector securely.
Is the machine head tilted back?
Return the machine head to
its normal position.