LH4-B800E6 - 6
6. ELECTRIC MECHANISM
Circuit board connectors
<Main circuit board>
P1 [FAN2]
Pin No. Signal name Symptoms resulting mainly from poor contact
1 +24V The inside air circulation fan does not operate.
Error E-41 is displayed.
2 FAN2 signal
30V
P4 [PANEL]
Pin No. Signal name Symptoms resulting mainly from poor contact
1 +5V The panel does not operate.
20V
3 KEY0
4 KEY1
5 KEY2
6OC
7A
8B
9C
10 D
11 E
12 F
13 G
14 STB
15 P8V
16 SENSOR
17 BUZZER
18 0V
19 0V
20 0V
P3 [SYNC]
Pin No. Signal name Symptoms resulting mainly from poor contact
1 +5V The machine motor does not turn.
A machine stopping error occurs.
One of error E-02, E-62, E-63 and E-64 is displayed.
2 Encoder signal
3 Needle up stop position signal
4 Needle down stop position signal