6. ELECTRIC MECHANISM
P16 [NPM]
Pin No. Signal name Symptoms resulting mainly from poor contact
1 Zigzag PM driving current A The zigzag home position can not be found.
The zigzag mechanism does not operate.
Error E-05 is displayed.
2 Zigzag PM driving current B
3 Zigzag PM driving current C
4 Zigzag PM driving current D
5 Zigzag PM driving current F
6-
P19 [OPSOL]
Pin No. Signal name Symptoms resulting mainly from poor contact
1 Spare solenoid The tension release solenoid does not operate.
2-
3 Tension release solenoid
4-
5 +40V
6 +40V
P20 [AC17/AC30V]
Pin No. Signal name Symptoms resulting mainly from poor contact
1 AC30V The tension release solenoid does not operate.
The control box fan does not operate.
One of error E-41 and E-42 is displayed.
2 AC30V
3-
4 AC17V
5 AC17V