141
BES-960BC.1260BC
Chapter 7 Electric Components
Connectors on the main PCB
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
Main PCB - Power supply PCB in control box (P27)
Main PCB - Bed retracting sensor
Unused
Main PCB - Power supply PCB in control box (P12)
Main PCB - Main shaft motor
Main PCB - Power supply PCB in control box (P19)
Main PCB - Y motor
Main PCB - X motor
Main PCB - Power supply PCB in control box (P3)
Main PCB - Thread trimmer motor 1
Main PCB - Thread trimmer motor 2
Main PCB - Cooling fan in control box
Main PCB - BC PCB
Main PCB - INDEX motor
Main shaft brake
Expansion signal
Bed retracting sensor
For testing
Inverter control power supply
Main shaft motor output
Main shaft motor power
supply
Y motor output
X motor output
+55 V power supply (X and Y motors,
and thread trimmer motor)
Thread trimmer motor 1 output
Thread trimmer motor 2 output
Cooling fan power supply
Cooling fan stop signal
Lower shaft drive signal
INDEX motor output
Main shaft brake remains
locked .
Red lamp is not lit even when
HEAD switch is on (thread
breakage sensor is activated).
Heads No. 2, 4, and 6 are
suspended.
Presser foot does not retract.
Error E-A1 appears when
embroidering is started.
Error E-A1 appears when
embroidering is started.
Error E-A1 appears when
embroidering is started.
Error E-14 appears when
power is turned on.
Error E-18 appears when
power is turned on.
Error E-B9 appears when
power is turned on.
Error E-B9 appears when
power is turned on.
Error E-B9 appears when
power is turned on.
Error E-E3 appears when
power is turned on.
Error E-B2 appears when
power is turned on.
Error E-07 appears when
needle bar is changed for
color change.
Connecting point Drive signal
Symptoms resulting from
improper connection or
breakage
Connector No.