179
BES-960BC.1260BC
Chapter 8. Finding Cause of Problem
The lower shaft module has an abnormality. • Turn off the machine power.
• Separate connectors P1, P3, and P5 for fixed bed or P2, P4, and P6 for retracting bed, from
the defective lower shaft module.
• Turn on the machine power.
Error E-B2 will occur. The green LEDs on the two machine heads controlled by the defective
BC PCB will blink. Press the HEAD switch on the machine head downward (off), and press
the MENDING switch upward until the green LED goes off.
• After all green LEDs go off, press the STOP key on the panel or step back key on the
machine head to cancel the error.
Note:
The operation above is to stop the operations of the lower shaft and lower shaft module which are connected to a defective BC PCB, resulting in causing
the corresponding machine head to pause. The pause can be canceled by turning on the machine power. When you want to stop the operations of the
lower shaft and lower shaft module again, return to step 3.
Comments to this Manuals