36
BES-960BC.1260BC
Chapter 2 Parts Replacement and Adjustment
START
!1
!1
q
10.Check that there is no error being displayed on the op-
eration panel. Then, while pressing the STOP key, press
the ( ) jog key. “tcut” will then appear on the display.
11.Press the ( ) jog key so that “CASE” appears ont he display,
and then press the START key. The display will now show
“xxx1”.
12.Turn the potentiometer
!1 all the way to the left as shown
in the illustration at left. When it is then turned gently to
the right, there will be a point where the buzzer on the
operation panel sounds.
• The point where the buzzer sounds is the potentiometer
!1 position for the first stitch. The display will appear as
shown in the illustration at left at this time.
13.While the buzzer is sounding, install the potentiometer
!1 to the change box by following the removal procedure
in reverse.
Note:
• Keep checking the buzzer to make sure that the po-
tentiometer
!1 does not move out of its adjusted po-
sition.
• Be careful not to move the needle position which was
adjusted in step
o either.
14.Once the potentiometer has been installed, press the
needle bar change key on the operation panel to move
the needle bar to needles 1 to 9 (BES-960BC) or needles
1 to 12 (BES-1260BC) in order to check the operation.
15.After carrying out the above checking operation, install
the color change cover
q.