6-10. Error code
When there is the possibility that harness is faulty, check connections and pin omissions, etc. with reference to "6-7-2.
Harness connecting pin number table”.
It is possible for it to be made not to indicate by setup of a DIP switch by error provisionally depending on the contents of
an error. However, set up after checking the safety of operation of a sewing machine in that case. Moreover, be sure to
remove the factor of abnormalities immediately and return a setup.
Error
code
Contents Disposal / factor / check
E-500
The abnormalities in 24V
system voltage (rise)
• Primary side input voltage is high.
• The secondary side connection mistake of the power supply unit
transformer 2
• Evasion by DIP switch B-5 ON is possible.
E-501
The abnormalities in 24V
system voltage (descent)
• The fuse F2 on a power supply board has run out.
• Primary side input voltage is low.
• The secondary side connection mistake of the power supply unit
transformer 2
• Evasion by DIP switch B-5 ON is possible.
E-502
The abnormalities in 36V
system voltage (rise)
• Primary side input voltage is high.
• Evasion by DIP switch B-5 ON is possible.
E-503
The abnormalities in 36V
system voltage (descent)
• The fuse F3 on a power supply board has run out.
• Primary side input voltage is low.
• The secondary side connection mistake of the power supply unit
transformer 2
• Evasion by DIP switch B-5 ON is possible.
E-504
The abnormalities in primary
side voltage (rise)
• Primary side input voltage is high.
• The primary side connection mistake of a transformer 1
E-505
The abnormalities in primary
side voltage (descent)
• Primary side input voltage is low.
• The primary side connection mistake of a transformer 1
• The fuses F2 and F3 on a power supply board have run out.
E-510
E-511
E-512
E-513
The needle bar is in positions
other than an upper needle
position. (WARNING)
• Turn the machine pulley to move the needle bar to its upper needle
position.
• Malfunction of machine sensor (needle up)
E-520
Upper thread breakage
(WARNING)
<Correct detection>
• Upper thread has broken.
<Incorrect detection (Upper thread has not broken.)>
• Poor adjustment of upper thread detector.
• Poor adjustment or dirt of an optical fiber tip position.
• Malfunction of upper thread detector
• Malfunction of machine sensor harness A or B.
• There are few stitch numbers before upper thread breakage is detected.
→DIP switch C-1 turn ON.
E-530
Sewing clamp and sewing
program number do not match.
<Correct detection>
• A number is made in match.
* Turn ON DIP switch B-1 and carry out error disregard.
(A data check is surely carried out.)
<Incorrect detection (Recognition of an actual jig pattern and a jig pattern
sensor is different.)>
• Malfunction of jig pattern PCB.
• Dirt is in photo sensors on jig pattern PCB.
• Malfunction of jig pattern harness.
E-535
Retractable are for double (0 to
31) but data does not contain a
double switching command.
(Model No. 0 - 31)
• The check of data (Input the double switching command.)
* Turn ON DIP switch B-6 and carry out error disregard.
(A data check and sewing clamp are surely carried out.)