6. ELECTRIC COMPONENTS
BAS-7610
6-47
6-10. Error code
When there is the possibility that harness is faulty, check connections and pin omissions, etc. with reference to "6-7-2.
Harness connecting pin number table”.
It is possible for it to be made not to indicate by setup of a DIP switch by error provisionally depending on the contents of
an error. However, set up after checking the safety of operation of a sewing machine in that case. Moreover, be sure to
remove the factor of abnormalities immediately and return a setup.
Error
code
Contents Disposal / factor / check
E-500
The abnormalities in 24V
system voltage (rise)
Primary side input voltage is high.
The secondary side connection mistake of the power supply unit
transformer 2
Evasion by DIP switch B-5 ON is possible.
E-501
The abnormalities in 24V
system voltage (descent)
The fuse F2 on a power supply board has run out.
Primary side input voltage is low.
The secondary side connection mistake of the power supply unit
transformer 2
Evasion by DIP switch B-5 ON is possible.
E-502
The abnormalities in 36V
system voltage (rise)
Primary side input voltage is high.
Evasion by DIP switch B-5 ON is possible.
E-503
The abnormalities in 36V
system voltage (descent)
The fuse F3 on a power supply board has run out.
Primary side input voltage is low.
The secondary side connection mistake of the power supply unit
transformer 2
Evasion by DIP switch B-5 ON is possible.
E-504
The abnormalities in primary
side voltage (rise)
Primary side input voltage is high.
The primary side connection mistake of a transformer 1
E-505
The abnormalities in primary
side voltage (descent)
Primary side input voltage is low.
The primary side connection mistake of a transformer 1
The fuses F2 and F3 on a power supply board have run out.
E-510
E-511
E-512
E-513
The needle bar is in positions
other than an upper needle
position. (WARNING)
Turn the machine pulley to move the needle bar to its upper needle
position.
Malfunction of machine sensor (needle up)
E-520
Upper thread breakage
(WARNING)
<Correct detection>
Upper thread has broken.
<Incorrect detection (Upper thread has not broken.)>
Poor adjustment of upper thread detector.
Poor adjustment or dirt of an optical fiber tip position.
Malfunction of upper thread detector
Malfunction of machine sensor harness A or B.
There are few stitch numbers before upper thread breakage is detected.
DIP switch C-1 turn ON.
E-530
Sewing clamp and sewing
program number do not match.
<Correct detection>
A number is made in match.
* Turn ON DIP switch B-1 and carry out error disregard.
(A data check is surely carried out.)
<Incorrect detection (Recognition of an actual jig pattern and a jig pattern
sensor is different.)>
Malfunction of jig pattern PCB.
Dirt is in photo sensors on jig pattern PCB.
Malfunction of jig pattern harness.
E-535
Retractable are for double (0 to
31) but data does not contain a
double switching command.
(Model No. 0 - 31)
The check of data (Input the double switching command.)
* Turn ON DIP switch B-6 and carry out error disregard.
(A data check and sewing clamp are surely carried out.)