Error code Possible cause Page
Err 700
(Overvoltage)
• Does the power supply voltage match the
control box voltage specifications?
Check the voltage.
Err 701
(Sewing machine
motor
overvoltage)
• Abnormal rise in sewing machine motor drive voltage.
Turn off the power switch and check the voltage.
*
Err 705
(Under voltage)
• Abnormal drop in power supply voltage.
Check the input voltage.
*
Err 710
(Overcurrent)
• Is the 9-pin or 11-pin connector inside the
control box disconnected?
Insert the connector securely.
*
Err 711
(Needle zigzag
motor
overcurrent)
• Problem with PMD P.C. board.
Replace the control box.
**
Err 740
(Cooling fan
problem)
• The cooling fan (1) inside the control box is
not working.
Check if it is blocked with thread scraps.
• Is the 3-pin connector inside the control box
disconnected?
Insert the connector securely.
*
*