6.ELECTRIC COMPONENTS
BAS-7610
6-50
E-903
Malfunction of folding base
cylinder or sensor
<Cylinder operates>
Disconnection or poor connection of the folding clamp sensor.
Poor adjustment of the folding clamp sensor.
<Cylinder does not operate>
Malfunction of solenoid valve No.5 or 6.
Poor connection of folding clamp valve harness No.5 or 6.
E-910 X axis positioning error
E-920 Y axis positioning error
Slack of a feed timing belt
The backlash of a feeding gear is large.
Disconnection or poor connection of the area sensor harness or the
area home position sensor.
Poor adjustment of the sensor position
E-960
The abnormalities in clamp in
sensor
Disconnection or poor connection of the clamp in sensor
Poor adjustment of the sensor dog.
E-970
Malfunction of work clamp
cylinder or sensor
<Cylinder operates>
Disconnection or poor connection of the work clamp sensor.
Poor adjustment of the work clamp sensor.
Evasion by DIP switch B-2 ON is possible.
<Cylinder does not operate>
Malfunction of solenoid valve No.4A or 4B.
Poor connection of folding clamp valve harness No.4A or 4B.