5. ADJUSTMENT
BAS-7610
5-34
5-30-3. Setting of sensitivity
It adjusts, after performing thread through to usual.
Procedure
Operation Volume indicator
1
The mode selection switch is changed to the "SET" side.
2
If the jog switch is pushed when thread is on a sensor line, "3" of the volume
indicator and "6" will blink. If the jog switch is detached within 3 seconds, "4" of
the volume indicator and "5" will blink and the quantity containing light in case
there is thread will be read. (If The mode selection switch is changed to the
"RUN" side while "4" of the volume indicator and "5" are blinking, the quantity
containing light will not be updated.)
3
Thread is removed from a sensor line and the jog switch is pushed.
4
Stable display light lights up and a sensitivity level is set up. A sensitivity level is
set up in the middle of quantity containing light the time of there being thread,
and in case there is nothing.
Sensitivity level display
100 grades lighting
10 grades blink
Grade of 1 nothing
Example 720-729
5
The mode selection switch is changed to the "RUN" side.
171 1S
Quantity containing light
Much
Little
Sensitivity level
There is a work.
There is no work.
1710S
1709S
1704S
1708S
1701S
1700S
1703S
1704S
1705S
1706S