■ Error code DD
Fuser unit failure except error code 6A, 6B, 6C, 6D, 6E, 6F, 76, 78, DE and E2.
■ Error code DE
When the center thermistor is higher than the idle temperature, it is detected that the side
thermistor temperature is lower than 60 °C.
Print Unable XX
See Troubleshooting and routine maintenance chapter in User's Guide.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step Cause Remedy
1
Harness connection failure
between fuser unit connector and
paper eject sensor PCB ASSY
Check the harness connection between the
fuser unit connector and paper eject sensor
PCB ASSY, and reconnect it.
2
Harness connection failure
between fuser unit connector and
low voltage power supply PCB
ASSY
Check the harness connection between the
fuser unit connector and low voltage power
supply PCB ASSY, and reconnect it.
3
Harness connection failure
between paper eject sensor PCB
and main PCB
Check the harness connection between the
paper eject sensor PCB and main PCB,
and reconnect it.
4
Paper eject sensor PCB failure Replace the paper eject sensor PCB
ASSY.
5
Low voltage power supply PCB
failure
Replace the low voltage power supply PCB
ASSY.
6 Main PCB failure Replace the main PCB ASSY.
7 Fuser unit failure Replace the fuser unit.
Print Unable XX
Turn the power off and then back on again.
<User Check>
• Turn OFF and ON the power and check if the machine recovers.
Step Cause Remedy
1
Harness connection failure
between paper eject sensor PCB
ASSY and fuser unit
Check the harness connection between the
paper eject sensor PCB ASSY and fuser
unit, and reconnect it.
2
Side thermistor or center
thermistor failure
Replace the fuser unit.
3
Paper eject sensor PCB failure Replace the paper eject sensor PCB
ASSY.
4 Main PCB failure Replace the main PCB ASSY.