2-45
Confidential
■ Error code 75
Cooling down the inside of the machine to protect it.
■ Error code 76
Fuser unit error. (The center thermistor detects the sharp temperature rise.)
Error code 78
Fuser unit error. (The center thermistor detects the sharp temperature fall.)
■ Error code 7A
A lock signal of the main motor cannot be detected.
Cooling Down
Wait for a while
<User Check>
• Leave the machine for a while as the power remains ON.
Step Cause Remedy
1 Internal temperature sensor failure Replace the internal temperature sensor.
2 Main PCB failure Replace the main PCB ASSY.
Print Unable 76
Turn the power off and then back on again.
Print Unable 78
Turn the power off and then back on again.
Step Cause Remedy
1 Fuser unit failure Replace the fuser unit.
2
Low voltage power supply PCB
failure
Replace the low voltage power supply PCB
ASSY.
3
Paper eject sensor PCB failure Replace the paper eject sensor PCB
ASSY.
4 Main PCB failure Replace the main PCB ASSY.
Print Unable 7A
Turn the power off and then back on again.
Step Cause Remedy
1
Flat cable connection failure of
main motor
Check the flat cable connection of the main
motor and reconnect them.
2 Main motor failure Replace the main motor.
3
Low voltage power supply PCB
failure
Replace the low voltage power supply PCB
ASSY.
4 Main PCB failure Replace the main PCB ASSY.