Page view 125
2-89
Confidential
Black band
Downward fogging of solid black
Horizontal lines
User Check
Clean the inside of the machine and the corona wire in the drum
unit. If the same problem occurs after cleaning, replace the drum
unit with a new one.
The paper tray ground terminal provided in the machine body may
be dirty. Clean the contact with a dry cloth.
Step Cause Remedy
1
Bend of tray ground spring (1)
Correct bending of the tray ground spring
.
(2) Replace the paper tray.
User Check
Replace the toner cartridge with a new one.
Step Cause Remedy
1
High voltage power supply PCB
ASSY failure
Replace the high voltage power supply
PCB ASSY.
2 Main PCB failure Replace the main PCB ASSY.
User Check
The paper tray ground terminal provided in the machine
body may be dirty. Clean the contact with a dry cloth.
Replace the drum unit with a new one.
Replace the toner cartridge with a new one.
Step Cause Remedy
1
Dirt on the electrodes of the drum
unit and the machine body
Clean the electrodes of the drum unit and
machine body. (Refer to Fig. 2-11, Fig. 2-
12.)
2
Bend of tray ground spring (1)
Correct bending of the tray ground spring
.
(2) Replace the paper tray.
3 Laser unit failure Replace the laser unit.
4
Scratch and Dirt on the heat roller
(horizontal stripes at 53.4 mm)
Replace the fuser unit.