Brother DCP-7057 Service Manual Page 136

  • Download
  • Add to my manuals
  • Print
  • Page
    / 337
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 135
2-99
Confidential
3.11 Troubleshooting of the Control Panel
3.11.1 Nothing is displayed on the LCD
3.11.2 The control panel does not work
3.11.3 Lamp malfunction
User Check
Verify if the power switch is turned off.
Step Cause Remedy
1 AC cord failure Replace the AC cord.
2
Harness connection failure of panel
PCB ASSY
Reconnect the panel PCB ASSY harness.
3
Harness connection failure of LCD
and panel PCB
Check the harness connection between
the LCD and panel PCB, and reconnect it.
4 LCD failure Replace the LCD.
5
Power switch holder failure Replace the power switch holder.
6
Low voltage power supply PCB
failure
Replace the low voltage power supply
PCB ASSY.
7 Panel PCB failure Replace the panel PCB ASSY.
8 Main PCB failure Replace the main PCB ASSY.
User Check
Check whether the function lock is not set.
Turn the power off and on.
Step Cause Remedy
1 Panel unit assembling failure Re-assemble the panel unit.
2
Connection failure between main
PCB and panel PCB
Connect the connector between the main
PCB ASSY and panel PCB ASSY
correctly.
3 Rubber key failure Replace the rubber key.
4 Panel PCB failure Replace the panel PCB ASSY.
5 Main PCB failure Replace the main PCB ASSY.
Step Cause Remedy
1
Connection between main PCB and
panel PCB
Connect the connector between the main
PCB ASSY and panel PCB ASSY
correctly.
2 Panel PCB failure Replace the panel PCB ASSY.
3 Main PCB failure Replace the main PCB ASSY.