Error code 6C
Fuser unit error. (The center thermistor does not detect 60 °C within the specified time.)
Error code 6D
Fuser unit error. (The center thermistor does not detect 60 °C within the specified time.)
Error code 6E
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
Error, which cannot be specified, occurs.
Print Unable 6C
Turn the power off and then back on again.
Print Unable 6D
Turn the power off and then back on again.
Step Cause Remedy
1
Fuser unit connector connection
failure
Check the connector connection of the
fuser unit and reconnect it.
2 Fuser unit failure Replace the fuser unit.
3
Low voltage power supply PCB
failure
Replace the low voltage power supply PCB
ASSY.
4
Paper eject sensor PCB failure Replace the paper eject sensor PCB
ASSY.
5 Main PCB failure Replace the main PCB ASSY.
Print Unable 6E
Turn the power off and then back on again.
<User Check>
Turn OFF the power switch, and turn it ON again after a while.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.