Error code F0
Flash ROM error.
Error code F1 to F6, F8
These errors do not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
Error, which cannot be specified, occurs.
Error code F9
The country code is not entered properly.
Error code FA to FF
These errors do not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
Error, which cannot be specified, occurs.
Print Unable
Turn the power off and then back on again.
<User Check>
Turn OFF the power switch, and turn it ON again after a while.
Step Cause Remedy
1 Malfunction of firmware Rewrite the latest firmware.
2 Main PCB failure Replace the main PCB ASSY.
---
<User Check>
Turn OFF the power switch, and turn it ON again after a while.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Machine Error F9
Step Cause Remedy
1
Power turned OFF while the
function code 74 is being executed
and “PARAMETER INTI” is being
displayed
Re-enter the country code.
(Refer to
"1.4.20 Setting by country
(Function code 74)" in Chapter 5
.)
---
<User Check>
Turn OFF the power switch, and turn it ON again after a while.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.